PD6310-7H2-WM

Price
$2,422.00 CAD
Stock
12 In Stock

  • Product Type: 1/8 DIN Batch Controller Digital Panel Meter W&M Approved
  • Inputs: Pulse
  • Outputs: 2 Relays
  • Power: 12-24 VDC/VAC
  • Transmitter Power: 5 or 10 VDC @ 50 mA or 24 VDC @ 100 mA
  • Display: SunBright, 0.6", Dual Line, 6 Digits, Red LED
  • Approvals: CE, UL/C-UL, NTEP
  • Warranty: 3 years

Specifications

Approvals & Certifications

  • ATEX II 2 GD, Ex d IIC T* Gb, Ex Tb IIIC T90° C Db IP68. Ta = -40 to +* °C. *T6 = -40 to + 60° C, *T5 = -40 to +65° C, Certificate Number: Sira 12-ATEX-1182
  • CE
  • CSA Class I, Div. 1, Groups B, C, D, Class II, Div. 1, Groups E, F, G, Class III, Div. 1: Class I, Zone 1 Ex d IIC, Zone 21 Ex Tb IIIC T90° C: -40° C < Tamb. < +60° C, Temperature Code T6 -40° C < Tamb. < 65° C, Temperature Code T5 Enclosure T
  • FM Class I, Div. 1, Groups B, C, D, Class II, Div. 1, Groups E, F, G, Class III, Div. 1, T5/T6, Class I, Zone 1, AEx d, IIC Gb T5/T6, Zone 21, AEx Tb IIIC T90° C, Ta -40° to 65° C T6 Ta = -40° to 60° C, T5 Ta = -40° to 65° C, Certificate Numbe
  • IEC Ex d IIC T* Gb, Ex Tb IIIC T90° C Db IP68. Ta = -40 to +* °C. *T6 = -40 to +60° C, *T5 = -40 to +65° Certificate Number: IECEx SIR 12.0073
  • UL

Environmental Protection

  • IP65
  • IP66
  • IP68
  • NEMA 4
  • NEMA 4X

Display

  • Upper display: 0.60” (15 mm) high. Lower display: 0.46” (12 mm) high. Both are 6 Digits (-99999 to 999999), Red LEDs. Both are 6 Digits (-99999 to 999999), Red LEDs, with Lead Zero Blanking.

Default Display Assignment

  • The upper display shows batch total. The Lower display shows rate with alternating units, and can be switched to show grand total, batch count, or preset with the STOP key

Custom Display Assignment

  • The upper and Lower displays may be assigned to rate, total, grand total, batch count, preset, Set Points, units (Lower display only), alternating R & T, R & GT, preset & rate, max. & min, or a Modbus display register. Any rate/total/grand total display may be Programmed to alternate with a custom unit or tag.

Alternating Display

  • Displays alternate every 10 seconds when display is selected or the batch is paused.

Display Intensity

  • Eight user-selectable intensity levels

Display Update Rate

  • 5/second (200 ms)

Overrange

  • Display flashes 999999

Underrange

  • Display flashes -99999

Operating Methods

  • Three Programmable Front Panel Buttons (Default START, BATCH, STOP), digital inputs, PC and MeterView Pro Software, and Modbus registers.

Programming Methods

  • Four Front Panel Buttons, digital inputs, PC and MeterView Pro Software, Modbus registers.

F4 Digital Input Contacts

  • 3.3 Vdc on Contact. Connect Normally Open Contacts across F4 to COM.

F4 Digital Input Logic Levels

  • Logic High: 3 to 5 Vdc Logic Low: 0 to 1.25 Vdc

Noise Filter

  • Programmable from 2 to 199 (0 will disable filter)

Filter Bypass

  • Programmable from 0.1 to 99.9 % of Calibrated Span

Recalibration

  • Recommended at Least every 12 months.

Maximum / Minimum Display

  • Maximum (Peak) / min (Valley) Readings Reached by the process are stored until reset by the user or until Power is cycled.

Password

  • Three Programmable passwords restrict modification of programmed settings and two prevent resetting the totals.

Non-Volatile Memory

  • All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost.

Power Options

  • 85-265 Vac 50/60 Hz, 90-265 Vdc, 20 W max or 12-24 Vdc ± 10 %, 15 W Max. Powered over USB for configuration only.

Fuse

  • Required External Fuse: UL Recognized, 5 A max., Slow Blow, up to 6 batch Controllers may share one 5 A fuse.

Isolated Transmitter Power Supply

  • Terminals P+ & P-: 24 Vdc ± 10 %. 12-24 Vdc Powered models selectable for 24, 10, or 5 Vdc Supply (Internal P+/P- switch). 85-265 Vac models rated @ 200 mA max., 12-24 Vdc Powered models rated @ 100 mA max., @ 50 mA max. for 5 or 10 Vdc Supply.

Normal Rejection Mode

  • Greater than 60 dB at 50/60 Hz Isolation: 4 kV Input/output-to-Power line. 500 V Input-to-output or output-to-P+ Supply.

Overvoltage Category

  • Installation Overvoltage Category II: Local level with smaller transient overvoltages than Installation Overvoltage Category III.

Environmental

  • Operating Temperature Range: -40 to 65° C
  • Storage Temperature Range: -40 to 85° C
  • Relative Humidity: 0 to 90 % Non-Condensing

Connections

  • Removable Screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external Relays, Digital I/O, and Serial communication Adapters

Enclosure

  • 1/8 DIN, High Impact Plastic, UL 94V-0, color: Black

Mounting

  • 1/8 DIN Panel cutout required: 3.622” x 1.772” (92 mm x 45 mm).

Weight

  • 9.5 oz. (269 g)

Dimensions

  • 4.68” x 2.45” x 5.64” (119 mm x 62 mm x 143 mm) (W x H x D)

USB Connection

  • Compatibility: USB 2.0 Standard, Compliant
  • Connector Type: Micro-B receptacle
  • Cable: USB A Male to Micro-B Cable
  • Driver: Windows® 98/SE, ME, 2000, Server 2003/2008, XP 32/64-Bit,
  • Vista 32/64-Bit, Windows® 7 32/64-Bit, Windows® 10 32/64-Bit
  • Power: USB Port
show more