PD2-6100-6H7

Price
$1,696.00 CAD
Stock
50+ In Stock

  • Product Type: Large Display NEMA 4X Strain Gauge / Load Cell Meter
  • Inputs: Strain Gauge, Load Cell, Millivolts
  • Outputs: 4 Relays & 4-20 mA Output
  • Power: 85-265 VAC, 90-265 VDC
  • Transmitter Power: 5 or 10 VDC @ 350 mA + 24 VDC @ 40 mA
  • Display: SunBright, 1.8", Dual Line, 6 Digits, Red LED
  • Serial Communications: RS-485 Modbus
  • Warranty: 3 years

Specifications

Display

  • Two lines with 1.8” (46 mm) High Digits, Red LEDs, 6 Digits per line (-99999 to 999999), with Lead Zero Blanking

Display Intensity

  • Eight intensity levels

Display Update Rate

  • 5/second (200 ms)

Overrange

  • Display flashes 999999

Underrange

  • Display flashes -99999

Display Assignment

  • The upper and Lower displays may be assigned to PV1, PV2, PCT (Percent), max/min, alternate max. & min, Set Points, units (Lower display only), or Modbus Input.

Programming Methods

  • Four SafeTouch through-glass buttons when cover is installed. Four internal pushbuttons when cover is removed.

F4 Digital Input Contacts

  • 3.3 Vdc on Contact. Connect Normally Open Contacts across F4 to COM.

F4 Digital Input Logic Levels

  • Logic High: 3 to 5 Vdc, Logic Low: 0 to 1.25 Vdc

Noise Filter

  • Programmable from 2 to 199 (0 will disable filter)

Filter Bypass

  • Programmable from 0.1 to 99.9 % of Calibrated Span

Recalibration

  • Calibrated at the factory. Recalibration is recommended at Least every 12 months.

Maximum / Minimum Display

  • Maximum/minimum readings reached by the process are stored until reset by the user or until power to the meter is turned off.

Password

  • Three Programmable passwords restrict modification of programmed settings.

Non-Volatile Memory

  • All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost.

Power Options

  • Powered over USB for configuration only.
  • 85-265 Vac 50/60 Hz, 90-265 Vdc, 20 W max
  • 12-24 Vdc ± 10 %, 15 W Max.

Fuse

  • Required External Fuse: UL Recognized, 5 A max., Slow Blow, up to 6 metres may share one 5 A fuse

Isolated Sensor Power Supply

  • (Note: Do not use 24 Vdc to power strain gauge bridge)
  • Terminals Ex+ & Ex-: 10 Vdc or 5 Vdc ± 10 %. Rated @ 350 mA max

Normal Mode Rejection

  • Greater than 60 dB at 50/60 Hz

Isolation

  • 4 kV Input/Output-to-Power Line, 500 V Input-to-Output or Output-to-P+ Supply

Overvoltage Category

  • Installation Overvoltage Category II: Local level with smaller transient overvoltages than Installation Overvoltage Category III.

Environmental

  • T6 Class Operating Temperature Range Ta = -40 to 60° C
  • T5 Class Operating Temperature Range Ta = -40 to 65° C

Maximum Power Dissipation

  • PD8 Series: Max. Power dissipation limited to 15.1 W. See PD8 instruction manual for additional details.

Connections

  • Removable Screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external Relays, Digital I/O, and Serial communication Adapters.

Enclosure

  • UL Type 4X, IP65 rated. Polycarbonate & glass blended plastic Case, color: gray. Includes four PG11 through-hole conduit openings, with two factory installed PG11, IP68, Black nylon threaded hole plugs with backing nuts.

Wall Mounting

  • Four (4) mounting holes provided for mounting meter to wall

Pipe Mounting

  • Optional Pipe Mounting Kit (PDA6260) Allows for Pipe Mounting. Sold Separately.

Dimensions

  • 10.63” x 12.59” x 4.77” (270 mm x 319.7 mm x 121.2 mm) (H x W x D)

Weight

  • 6.10 lbs (2.76 kg)

UL File Number

  • UL & C-UL Listed. E160849, 508 Industrial Control Equipment

Warranty

  • 3 Years Parts & Labor

USB Connection

  • Compatibility: USB 2.0 Standard, Compliant Connector Type: Micro-B receptacle
  • Driver: Windows® 98/SE, ME, 2000, Server 2003/2008, XP 32/64-Bit, Vista 32/64-Bit, Windows 7 32/64-Bit, Windows 10 32/64-Bit
  • Power: USB Port
  • Cable: USB A Male to Micro-B Cable
show more