Portaflow PT400 Portable Transit Time Flow Meter

Brand: Pulsar Measurement

Recommended for clean fluids like water, glycol, oil and most chemicals.  

Sensors can be mounted without shutting down flow and there is no obstruction or pressure drop.  

The ultrasonic signal travels through all common metal and plastic pipe materials.  

Flow rate and totalizer are displayed continuously along with battery status, signal strength.  

Press one key to instantly change the units of flow measurement (e.g. from gallons to liters). 

Real time flow can be displayed in large numeric values or as a graph.

Portaflow calibration is easy with the onscreen menu system.  

Enter the pipe diameter, wall thickness and pipe material, and the PT400 calculates the optimum mounting method and separation distance for the sensors.

The Portaflow PT400 ultrasonic sensors clamp on the outside of vertical or horizontal pipes.  

Select a Sensor pair for the range of pipe sizes you will monitor:
  • 'A' Transducers for 0.51" to 4.5" Outside Diameter (13 to 115  mm)
  • 'B' Transducers for 2” to 39.37” Outside Diameter (50 to 1,000 mm)
Calibration parameters can be stored for up to twenty different sites so that operators can recall calibration setups from the Portaflow memory.

Use the 5V pulse or 4-20mA output to transmit to external devices like data loggers or recorders.

The PT400 includes 'A' or 'B' sensor pairs, stainless steel guiderail and mounting clamps, sensor cables, coupling compound and AC charger with a rugged polypropylene carry case.  

It operates up to 16 hours from internal batteries and recharges overnight.

Contact Greyline Instruments for specific recommendations in your application.
Features
  • Clamp-on Ultrasonic Sensors
  • Choose Small Pipe or Large Pipe Sensors
  • Internal Battery and/or AC Powered
  • Easy Calibration and Set-up
  • Flow Proportionate Pulse Output
  • 4-20 mA Output

Specifications

Certifications & Approvals

  • CE

Flow Rate

  • 0.65 to 40 ft/sec (0.2 to 12 m/sec)

Pipe Size

  • ‘A’ Transducers: 0.51" to 4.5" Outside Diameter (13 to 115 mm)
  • ‘B’ Transducers: 2” to 39.37” Outside Diameter (50 to 1,000 mm)

Pipe Wall Thickness

  • 0.039" to 2.95” (1 to 75 mm)

Pipe Material

  • Carbon Steel, Stainless Steel, PVC, PVDF, Fiberglass, Galvanized Steel, Mild Steel, Glass, Copper, Brass

Display

  • Backlit 64 x 240 Pixel LCD

Power Input

  • Built-in Rechargeable NiMH Battery
  • External Charger Operates from 90-264 VAC

Output

  • 0/4-20 mA, 5 V Pulse (1 Pulse/sec Maximum)

Operating Temperature

  • Electronics: 32° to 122° F (0° to 50° C)
  • Sensor: -4° to 275° F (-20° to 135° C)

Storage Temperature

  • 14° to 140° F (-10° to 60° C)

Environmental Protection

  • IP54

Accuracy

  • ± 2% of Reading
  • Repeatability: ±0.5%

show more