Series TFP-GV Gas Turbine Flow Meter

Brand: Dwyer Instruments, LLC

The Series TFP-GV Gas Flowmeters utilize a turbine wheel and electro-optical detection to convert flow rates into a linear 0 to 5 Vdc output signal for recording and data logging.

Couple this unit with a Series FIV Flow Totalizer for a remote flow monitoring display. A power adapter or mating cable assembly is required for operation.
Features
  • Corrosion Resistant PPS Body
  • High Repeatability with Patented Microturbine Design
  • Design Accurately Measures Flow Rates with No Zero Drift and No Required Maintenance

Models matching criteria: 11
  • Range - 2.1 to 11 SCFH (1 to 5 L/min)
50+ In Stock
$1,081.00 CAD
$10.00 Shipping
  • Range - 0.21 to 1.1 SCFH (0.1 to 0.5 L/min)
50+ In Stock
$2,455.00 CAD
$10.00 Shipping
  • Range - 0.42 to 2.1 SCFH (0.2 to 1 L/min)
50+ In Stock
$2,540.00 CAD
$10.00 Shipping
  • Range - 42 to 210 SCFH (20 to 100 L/min)
50+ In Stock
$2,117.00 CAD
$10.00 Shipping
  • Range - 21 to 110 SCFH (10 to 50 L/min)
50+ In Stock
$2,122.00 CAD
$10.00 Shipping
  • Range - 85 to 420 SCFH (40 to 200 L/min)
25+ In Stock
$1,620.00 CAD
$10.00 Shipping
  • Range - 8.5 to 42 SCFH (4 to 20 L/min)
25+ In Stock
$1,888.00 CAD
$10.00 Shipping
  • Range - 0.085 to 0.42 SCFH (0.04 to 0.2 L/min)
24 In Stock
$1,031.00 CAD
$10.00 Shipping
  • Range - 0.85 to 4.2 SCFH (0.4 to 2 L/min)
19 In Stock
$1,660.00 CAD
$10.00 Shipping
  • Range - 4.2 to 21 SCFH (2 to 10 L/min)
18 In Stock
$742.00 CAD
$10.00 Shipping
  • Range - 0.042 to 0.21 SCFH (0.02 to 0.1 L/min)
8 In Stock
$1,723.00 CAD
$10.00 Shipping

Specifications

Accuracy

  • ± 3 % of Full Scale

Air Consumption

  • 0.042 to 420 scfh (0.02 to 200 LPM)

Approvals & Certifications

  • CE

Consumption

  • 35 mA at 12 Vdc

Elastomers

  • Fluoroelastomer

Electrical Connectors

  • 4-Pin Power & Signal Connector

Environmental Protection

  • IP10
  • NEMA 1

Linearization

  • ± 3 % of Full Scale

Media

  • Gas

Output

  • 0-5 Vdc

Power

  • 115 Vac Power Adapter
  • 230 Vac Power Adapter

Power Requirement

  • 11.5-15 Vdc

Pressure Range

  • bar: 0 to 2.8
  • kPa: 0 to 280
  • psig: 0 to 40

Repeatability

  • ± 0.5 % of Full Scale

Sensitivity

  • ± 0.2 % of Full Scale Per °C

Storage Temperature

  • 0° to 70° C (32° to 158° F)

Temperature Range

  • 5° to 55° C (41° to 131° F)

Tube Connection

  • 1/2” Compression Fitting
  • 1/4” Compression Fitting
  • 1/8” Compression Fitting
  • 3/8” Compression Fitting

Wetted Materials

  • Acetal
  • Epoxy
  • Fluoroelastomer
  • Glass
  • PPS
  • Sapphire

  • Industrial Flow Monitoring
  • Commercial Systems
  • Laboratory Equipment

show more