LMH Hydraulic Transmitter
Brand: Winters Instruments
Specifications
- Developed for use in heavy duty industrial applications
- Compact stainless steel construction with welded stainless steel sensor
- Available ranges from psi: 0 to 8,700 (kPa: 0 to 60,000, bar: 0 to 600)
- Wide range of mechanical and electrical connections
- ±0.5% accuracy
- NEMA 4X / IP65 and IP67
- CE and RoHS compliant
- Customizable
Displaying prices & availability for Ohio, United States in CAD. Change location.
Models matching criteria: 11
- Pressure Range - psi: 0 to 870
100+ In Stock
$2,412.00
CAD
$10.00 Shipping
- Pressure Range - psi: 0 to 230
100+ In Stock
$890.00
CAD
$10.00 Shipping
- Pressure Range - psi: 0 to 580
100+ In Stock
$62.00
CAD
$10.00 Shipping
- Pressure Range - psi: 0 to 5,800
50+ In Stock
$1,886.00
CAD
$10.00 Shipping
- Pressure Range - psi: 0 to 8,700
50+ In Stock
$351.00
CAD
$10.00 Shipping
- Pressure Range - psi: 0 to 100
50+ In Stock
$2,435.00
CAD
$10.00 Shipping
- Pressure Range - psi: 0 to 1,500
50+ In Stock
$2,221.00
CAD
$10.00 Shipping
- Pressure Range - psi: 0 to 2,300
50+ In Stock
$2,366.00
CAD
$10.00 Shipping
- Pressure Range - psi: 0 to 360
25+ In Stock
$2,316.00
CAD
$10.00 Shipping
- Pressure Range - psi: 0 to 145
25+ In Stock
$1,038.00
CAD
$10.00 Shipping
- Pressure Range - psi: 0 to 3,600
21 In Stock
$1,067.00
CAD
$10.00 Shipping
Specifications
Brand
Accuracy
- ± 0.5 % of Full Scale Output
Approvals & Certifications
- CE
- EMC Directive: 2004/108/EC
- PED: 97/23/EC (Module A), Valid for Devices With, Max.
- RoHS
BSP Connection
- G 1/4” Male (DIN 3852)
Burst Pressure
- psi: 406 to 21,755 (kPa: 2,800 to 150,000, bar: 28 to 1,500)
Circuit Protection
- EMI/RFI Protected: Emission & Immunity According to EN 61326
- Reverse Polarity Protection
- Short Circuit Protected
Compensated Temperature
- 0° to 70° C (32° to 158° F)
Consumption
- Current Consumption 2-Wire: 25 mA - Max.
- Current Consumption 3-Wire Ratiometric: 3 mA
- Current Consumption 3-Wire Voltage: 5 mA (Short-Circuit Current 20 mA)
Electrical Connectors
- 1/2” NPT Female Conduit Fitting
- DIN 43650-A (ISO 4400)
- M12 x 1, 4-Pin
- Micro Connector (Contact Distance 9.4 mm)
Enclosure, Body Material
- 304 Stainless Steel
Environmental Protection
- IP65
- IP67
- NEMA 4X
Frequency
- Measuring Rate: 1 kHz
Load
- 3-Wire Rmin: 10 kiloohms
Load Effect
- 0.05 % of Full Scale Output / kiloohms
Materials of Construction
- Pressure Port: 316Ti Stainless Steel
NPT Connection
- Pressure Port: 1/4” NPT Male
Output
- 2-Wire: 4-20 mA/Vs = 8-32 Vdc
- 3-Wire Ratiometric: 0.5-4.5 Vs / Vs = 5 ± 0.5 Vdc
- 3-Wire: 0-10 V/Vs = 14-30 Vdc
Overpressure & Static Pressure Limits
- Overpressure psi: 203 to 17,405 (kPa: 1,400 to 120,000, bar: 14 to 1,200)
Power Supply Effect
- 0.05 % of Full Scale Output / 10 V
Pressure Range
- bar: 0 to 599.8
- kPa: 0 to 59,984
- psi: 0 to 8,700
Process Temperature
- -40° to 125° C (-40° to 257° F)
Response Time
- 2-Wire: ≤ 10 milliseconds
- 3-Wire: ≤ 3 milliseconds
Sensor, Probe Material
- Sensor: Welded Stainless Steel
Shock
- 500 G, 1 millisecond According to DIN EN 60068-2-27
Stability
- Long-term Stability: < ± 0.3 % of Full Scale Output/Year at Reference Conditions
Storage Temperature
- -40° to 85° C (-40° to 185° F)
Temperature Effect
- < ± 0.3 % of Full Scale Output/10 K
Temperature Range
- Electronics Environment: -40° to 85° C (-40° to 185° F)
Vibration
- 20 G at 25 Hz to 2 kHz According to DIN EN 60068-2-6
- Developed for use in Heavy Duty Industrial Applications
- Suitable for Heavy Duty Process & Automation Control Including Mobile Hydraulics & Presses