T280 Isolated Universal 2-Wire Transmitter
Brand: EurothermThe T280 is an isolated, 2-wire temperature and mV input transmitter designed to fit in a standard industrial thermal-head.
The T280 supports Pt-100 RTD and thermocouple inputs as well as voltages up to 100 mV.
Thermocouples supported include B, E, J, K, L, N, R, S and T.
If thermal-head mounting is not required, the T280 can either be mounted directly on a bulkhead or to a DIN rail using the included DIN rail clip.
Features- Universal input reduces inventory levels
- Eliminates ground loops
- Low profile design
- Hinged cover protects potentiometers from the environment
- Embedded terminals
Specifications
Brand
Adjustment
- Input Span: ± 15 % for Both Zero & Span
Approvals & Certifications
- CE Compliance Per EMC Directive 89/3/36 EEC
Burn-Out
- Burn-Out Detection: Upscale
Humidity
- 0 to 95 % Relative Humidity, Non-Condensing
Input
- 100 mV, Max.
- Input Span RTD: 20° C (68° F) Min.
- Input Span RTD: 500° C (932° F) - Max.
- Input SpaN Thermocouple: 5 mV Min.
Isolation
- 1,000 Vdc
Linearity
- Thermocouple/mV, RTD: Better than ± 0.1 % of Span, Linear to mV Input, Temperature
Mounting
- DIN Rail
Operating Temperature
- -20° to 70° C (-4° to 158° F)
Output
- Output Span: 4-20 mA, Limiting at < 28 mA
RTD Type
- Pt-100, 2-Wire or 3-Wire
Sensor, Probe Type
- B Thermocouple
- E Thermocouple
- J Thermocouple
- K Thermocouple
- L Thermocouple
- N Thermocouple
- R Thermocouple
- S Thermocouple
- T Thermocouple
Stability
- Thermocouple/mV, RTD: 0.02 % of Span/°C (25 mV Input), (100° C Span)
Supply Voltage
- 10-40 Vdc Polarity Protected
Temperature Coefficient
- Thermocouple CJC: < 0.05° C/°C of Ambient Temperature
Temperature Range
- RTD: -200° to 500° C (-328° to 932° F)
- Thermocouple: -270° to 1,500° C (-454° to 2,732° F)