Ambient Temperature Range
- -40° to 93.3° C (-40° to 200° F)
Exhaust Capacity - Relieving Units Only
- 40 scfm (65 m³/hour) where Downstream Pressure is psig: 5 (bar: 0.35, kPa: 35) Above psig: 20 (bar: 1.5, kPa: 150) Set Point
Flow Capacity
- 150 scfm (255 m³/hour) at psig: 100 (kPa: 700, bar: 7) Supply & psig: 20 (kPa: 150, bar: 1.5) Set Point
NPT Connection
- 1/2” NPT Female
- 3/4” NPT Female
- 3/8” NPT Female
Pressure Range
- bar: 0 to 10
- kPa: 0 to 1,000
- psig: 0 to 150
Signal or Output Pressure - Maximum
- psig: 150 (kPa: 1,000, bar: 10)
Supply Pressure - Maximum
- bar: 17
- kPa: 1,700
- psig: 250
Supply Pressure Effect
- Less than psig: 0.1 (bar: 0.07, kPa: 0.7) Per psig: 100 (bar: 7, kPa: 700) Change