Model 2500P 24 Vdc DIN Rail Power Supply

Brand: Eurotherm

Ideal for use with the 2500 I/O controller, the 2500P delivers a range of high performance, DIN rail mounted switched-mode power supplies, that easily meet the demanding requirements of modern technical specifications, while remaining cost effective.

The highly stable 24 Vdc supplies come in three current ratings 2.5 A, 5 A and 10 A. 

A novel retaining system allows easy DIN rail attachment, just insert and click into place, with no tools required for assembly or removal.

The 2500P range has every thing neatly arranged on the clearly and well-labelled front panel. 

The terminals, comprising convenient plug and socket connectors are easily accessible, positioned on the front edge of the device. 

A front panel mounted switch allows easy selection of mains supply voltage.
Features
  • Size
  • DIN rail mounting
  • Diode de-coupled output
  • Relay and LED indication
  • Reserve capability
  • 20 Milliseconds hold-up time
  • Reliability
  • Three year warranty

Specifications

Brand

Approvals & Certifications

  • EN 61000-4-5, EN 61000-4-11

Approvals & Certifications

  • CE
  • EMC Emissions: EN 50081-1 Includes EN 50081-2, Class B (EN 55011, EN 55022), Immunity: EN 50082-2 (Includes EN 50082-1)
  • IEC 801-2, 3, 4, 6 (EN 61000-4-2, EN 61000-4-4, ENV 50140, ENV 50141)

Current

  • Inrush Current: < 15 A - 5 A Model
  • Inrush Current: < 25 A - 2.5 A Model
  • Inrush Current: < 30 A - 10 A Model
  • Output Current: 10 A - 2500/10A
  • Output Current: 2.5 A - 2500P/2A5
  • Output Current: 5 A - 2500/5A0
  • Supply Current: < 2.6 A at 230 V - 10 A Model
  • Supply Current: < 6 A at 115 V - 10 A Model
  • Supply Current: 0.7 A at 230 V - 2.5 A Model
  • Supply Current: 1.3 A at 115 V - 2.5 A Model
  • Supply Current: 1.4 A at 230 V - 5 A Model
  • Supply Current: 2.6 A at 115 V - 5 A Model

Delay Time

  • Start Up Delay: 0.1 seconds Typical
  • Start Up Delay: 5 to 20 milliseconds Depending on Load

Display

  • LED Display

Environmental Protection

  • IP20

Frequency

  • Supply Frequency: 47 to 63 Hz

Input

  • Recommended Input Fusing: 10 A Circuit Breaker

Isolation

  • Alarm Relay (Relay Contact to Output): 500 Vdc

Mounting

  • Clip-On DIN Rail Mounting Typical TS35

Operating Temperature

  • -10° to 60° C (14° to 140° F)

Output

  • Alarm Relay (Contacts Close): > 22.1 V ± 4 %
  • Alarm Relay (Contacts Open): 19.8 V ± 4 % (When Output Falls Below)
  • Output Voltage at Nominal Power: 24 Vdc ± 0.5 %

Power

  • Alarm Relay (Switchable Power): 1 A at 28 Vdc

Storage Temperature

  • -25° to 85° C (-13° to 185° F)

Supply Voltage

  • 176-264 Vac
  • 85-132 Vac

Update Time

  • Hold-Up Time: > 20 millisecondss (196 Vac Full Load)

Voltage

  • Alarm Relay, Max.

show more