Approvals & Certifications
Approvals & Certifications
- CE
- EMC
- Emissions & Immunity: BS EN 61326
- FDA Regulation 21 CFR
- IEC 584.1, 751
- UL E57766
Battery Life
- Back-Up Battery of Replacement Period: 3-Years
- Back-Up Battery of Support Time (RTC): 1-Year Min. with Recorder UnPowered
Cable Length
- Ethernet Communication: Max.
Channels
- 18 - 6100A
- 48 - 6180A
- Virtual Channels: 36 to 128
Circuit Protection
- Open Circuit Detection: ± 57 NA
Communication
- 10/100 BaseT Ethernet (IEEE 802.3)
- ASCII Protocol Printer Support (Typical Applications: Input of ASCII String Inputs from barcode Readers, Credit Card Readers etc)
- BOOTP
- DHCP
- EIA-422
- Ethernet TCP/IP
- FTP
- ICMP
- Modbus RTU Master & Slave
- SMTP
- SNTP
- Transmission Standard: EIA-232
- Transmission Standard: EIA-485
- USB Plug & Play
Current
- Thermocouple of Bias Current: 0.05 NA
- Transmitter PSU of, Max.
Display
- 12.1” XGA (1,024 x 768 Pixels) - 6180A
- 5.5” 1/4 VGA (320 x 240 Pixels) - 6100A
- Colour TFT LCD with Cold Cathode Backlight, Fitted with Resistive, Analog, Touch-Panel
Electrical Connectors
- CAT5 Cable
- Termination: Edge Connector/Terminal Block
- Termination: RJ45
Electrical Rating
- AC Load Rating: 2 A at 250 V, 500 VA
Environmental Protection
- 6100A Portable Case Option: IP21
- Protection Bezel & Display: IP66
- Sleeve: IP20
Humidity
- Operation: 5 to 80 % Relative Humidity
- Storage: 5 to 90 % Relative Humidity
Input
- -150 mV to 20 V
- 2/3-Wire RTD Contact Closure (Not Channels 1, 7, 13, 19, 25, 31, 37, 43) > 60 Miiliseconds
- Channel to Channel: 2,500 Vac (Dielectric Strength)
- Channel to Ground: 1,500 Vac (Dielectric Strength)
- Event Input of Current Sink (Voltage I/P): 10 mA
- Maximum
- Over Voltage Protection: 50 V Peak (150 V with Attenuator)
- Recognition Levels Active: -30 to 0.8 V
- Recognition Levels Inactive: 2-30 V
Input Impedance
- 20 V Range: 65.3 kiloohms
- 38 mV, 150 mV, 1 V Ranges: > 10 megaohms
Insulation
- Terminals to Ground, Event Input to Ground: 50 Vrms or Dc (Basic, Double Insulation)
Isolation
- Channel to Channel, Channel to Common Electronics, Channel to Ground: 300 Vrms or Dc (Double Insulation)
Linearization
- RTD Typical of, Max.
- Thermocouple Typical of, Max.
Operating Temperature
- 0° to 50° C (32° to 122° F)
Power Requirement
- Poly-Carbonmonofluoride / Lithium Batteries
Power Supply
- 24 V Isolated Transmitter Power Supply
Pulse Range
- Minimum Pulse Width: 62.5 milliseconds
Resistance
- Contact Resistance Event: Active if Resistance 200 kiloohms
- Minimum Break Resistance: 10 megaohms
Resolution
- Input: 1.4 to 720 µV
- Input: 5 to 148 milliohms
RTD Type
- Cu10
- Cu53
- JPt100
- Ni100
- Ni120
- Pt100
- Pt1000
- Pt100A
Sample Rate
- 125 milliseconds Parallel Sampling
- Input/Relay Output Sample Rate: 8 Hz
Sensor, Probe Type
- B Thermocouple
- C Thermocouple
- D Thermocouple
- E Thermocouple
- G2 Thermocouple
- J Thermocouple
- K Thermocouple
- L Thermocouple
- Ni/NiMo Thermocouple
- NiMo/NiCo Thermocouple
- N Thermocouple
- PL2 Thermocouple
- R Thermocouple
- S Thermocouple
- T Thermocouple
- U Thermocouple
Storage Temperature
- -20° to 60° C (-4° to 140° F)
Supply Voltage
- 100-230 Vac ± 15 %, 47 to 63 Hz
- 110/120 Vac: 100 mA (Transmitter PSU)
- 110-370 Vdc
- 220/240 Vac: 63 mA (Transmitter PSU)
Temperature Effect
- Worst Case Temperature Performance Input Per °C: 25 to 388 ppm
Temperature Range
- RTD Typical: -220° to 850° C (-364° to 1,562° F)
- Thermocouple Typical: -270° to 2,495° C (-454° to 4,523° F)
Vibration
- 10 to 150 Hz: BS EN 60873, Section 9,18
Voltage
- Output Voltage: 25 V Nominal
- The Rate Impulse Voltage for Equipment on Nominal 230 V Mains is 2,500 V