UFM 3030 Ultrasonic Flowmeter
Brand: KrohneUFM 3030 is a 3-beam ultrasonic flowmeter for liquids. UFM 3030 measures independent of conductivity, viscosity, temperature, density and pressure.
Features- Three beams generate a measurement effectively independent of flow profile
- Major performance improvement by applying innovative electronics and digital signal processing (DSP)
- Optional pressure and temperature inputs for calculation of standardised volumetric flow or mass flow according to API 2540 or customer specifics
- Over 20.000 ultrasonic flowmeters installed worldwide
- Easy to install and operate
- No moving or intruding parts, no wear, no drift, therefore no additional pressure loss
- No material build-up as unobstructed flow sensor with smooth surface finish
- No periodic re-calibration or maintenance
- Insensitive to corrosive or abrasive products
- Excellent long-term stability and reliability
Specifications
Brand
Ambient Temperature Range
- -40° to 65° C (-40° to 149° F)
Applications
- Allocation Measurement
- Chemical Industry
- Control of Batching & Blending Operations
- District Heating
- Energy Measurement
- HVac Systems
- Irrigation Systems
- Mass Flow Measurement
- Metering of Cooling Water & Demineralised Water
- Oil & Gas Applications
- Petrochemical
- Power Plants
- Water
Approvals & Certifications
- API 2540
- IEC 529
Approvals & Certifications
- ATEX II 2 G EEx Ib IIC T6 to T3, II 2 G EEx d [ib] IIC T6 or II 2 G EEx de [ib] II C T6, II 2 G EEx d [ia/ib] IIC T6 or II 2 G EEx de [ia/ib] II C T6, II 2 G EEx d [ib] IIC T6 to T3 or II 2 G EEx de [ib] II C T6 to T3, II 2 G EEx d [ia/ib] IIC T6 to T3 Or
- CE
- CSA Class I, Div. 1 & 2, Groups A, B, C, D, CSA Class II, Div. 1 & 2, Groups E, F, G, CSA Class III, Div. 1
- FM Class I, Div. 1 & 2, Groups A, B, C, D, Class II, Div. 1, Groups E, F, G, & Div. 2, Groups F, G, Class III, Div. 1 & 2
- NAMUR NE 43
Cable Length
- 15 to 90 feet (5 to 30 metres)
Calibration
- Two Point Calibration, with Water
Communication
- HART
- PROFIBUS PA
Connection Material
- Aluminum, Polyurethane Coated - Box
- Stainless Steel - Box
Consumption
- Power: 10 VA
- Power: 10 W
Display
- Backlit Local Display with Three Push Buttons
- LCD Display
Duty Cycle
- 25 to 500 milliseconds - Pulse Output
Electrical Connectors
- 1/2” NPT
- 1/2” PF
- M20 x 1.5
Enclosure Finish
- Silver Paint
Enclosure, Body Material
- 316L Stainless Steel
- Carbon Steel
Environmental Protection
- IP65
- IP67
- IP68
- NEMA 4
- NEMA 4X
- NEMA 6
- NEMA 6P
Flange Material
- 316L Stainless Steel
- Carbon Steel
Flange Size - 1-1/2” (DN 40)
- 1-1/2” (DN 40) - 150# ASME B16.5
- 1-1/2” (DN 40) - JIS 20K
- 1-1/2” (DN 40) - PN 40
Flange Size - 1-1/4” (DN 32)
- 1-1/4” (DN 32) - 150# ASME B16.5
- 1-1/4” (DN 32) - JIS 20K
- 1-1/4” (DN 32) - PN 40
Flange Size - 1” (DN 25)
- 1” (DN 25) - 150# ASME B16.5
- 1” (DN 25) - JIS 20K
- 1” (DN 25) - PN 40
Flange Size - 10” (DN 250)
- 10” (DN 250) - 150# ASME B16.5
- 10” (DN 250) - 300# ASME B16.5
- 10” (DN 250) - JIS 10K
- 10” (DN 250) - PN 10
- 10” (DN 250) - PN 16
- 10” (DN 250) - PN 25
- 10” (DN 250) - PN 40
Flange Size - 12” (DN 300)
- 12” (DN 300) - 150# ASME B16.5
- 12” (DN 300) - 300# ASME B16.5
- 12” (DN 300) - JIS 10K
- 12” (DN 300) - PN 10
- 12” (DN 300) - PN 16
- 12” (DN 300) - PN 25
- 12” (DN 300) - PN 40
Flange Size - 14” (DN 350)
- 14” (DN 350) - 150# ASME B16.5
- 14” (DN 350) - 300# ASME B16.5
- 14” (DN 350) - PN 10
- 14” (DN 350) - PN 16
- 14” (DN 350) - PN 25
Flange Size - 16” (DN 400)
- 16” (DN 400) - 150# ASME B16.5
- 16” (DN 400) - 300# ASME B16.5
- 16” (DN 400) - PN 10
- 16” (DN 400) - PN 16
- 16” (DN 400) - PN 25
Flange Size - 18” (DN 450)
- 18” (DN 450) - 150# ASME B16.5
- 18” (DN 450) - PN 10
- 18” (DN 450) - PN 16
- 18” (DN 450) - PN 25
Flange Size - 2-1/2” (DN 65)
- 2-1/2” (DN 65) - 150# ASME B16.5
- 2-1/2” (DN 65) - JIS 10K
- 2-1/2” (DN 65) - PN 40
Flange Size - 2” (DN 50)
- 2” (DN 50) - 150# ASME B16.5
- 2” (DN 50) - JIS 10K
- 2” (DN 50) - PN 40
Flange Size - 20” (DN 500)
- 20” (DN 500) - 150# ASME B16.5
- 20” (DN 500) - 300# ASME B16.5
- 20” (DN 500) - PN 10
- 20” (DN 500) - PN 16
- 20” (DN 500) - PN 25
Flange Size - 24” (DN 600)
- 24” (DN 600) - 150# ASME B16.5
- 24” (DN 600) - 300# ASME B16.5
- 24” (DN 600) - PN 10
- 24” (DN 600) - PN 16
- 24” (DN 600) - PN 25
Flange Size - 28” (DN 700)
- 28” (DN 700) - 150# (ASME B16.47, A)
- 28” (DN 700) - PN 10
Flange Size - 3” (DN 80)
- 3” (DN 80) - 150# ASME B16.5
- 3” (DN 80) - 300# ASME B16.5
- 3” (DN 80) - JIS 10K
- 3” (DN 80) - PN 40
Flange Size - 32” (DN 800)
- 32” (DN 800) - 150# (ASME B16.47, A)
- 32” (DN 800) - PN 10
Flange Size - 36” (DN 900)
- 36” (DN 900) - 150# (ASME B16.47, A)
- 36” (DN 900) - PN 10
Flange Size - 4” (DN 100)
- 4” (DN 100) - 150# ASME B16.5
- 4” (DN 100) - 300# ASME B16.5
- 4” (DN 100) - JIS 10K
- 4” (DN 100) - PN 16
- 4” (DN 100) - PN 25
- 4” (DN 100) - PN 40
Flange Size - 40” (DN 1000)
- 40” (DN 1000) - 150# (ASME B16.47, A)
- 40” (DN 1000) - PN 10
Flange Size - 48” (DN 1200)
- 48” (DN 1200) - 150# (ASME B16.47, A)
- 48” (DN 1200) - PN 6
Flange Size - 5” (DN 125)
- 5” (DN 125) - 150# ASME B16.5
- 5” (DN 125) - 300# ASME B16.5
- 5” (DN 125) - JIS 10K
- 5” (DN 125) - PN 16
- 5” (DN 125) - PN 25
- 5” (DN 125) - PN 40
Flange Size - 56” (DN 1400)
- 56” (DN 1400) - 150# (ASME B16.47, A)
- 56” (DN 1400) - PN 6
Flange Size - 6” (DN 150)
- 6” (DN 150) - 150# ASME B16.5
- 6” (DN 150) - 300# ASME B16.5
- 6” (DN 150) - JIS 10K
- 6” (DN 150) - PN 16
- 6” (DN 150) - PN 25
- 6” (DN 150) - PN 40
Flange Size - 64” (DN 1600)
- 64” (DN 1600) - 150# (ASME B16.47, A)
- 64” (DN 1600) - PN 6
Flange Size - 72” (DN 1800)
- 72” (DN 1800) - 150# (ASME B16.47, A)
- 72” (DN 1800) - PN 6
Flange Size - 8” (DN 200)
- 8” (DN 200) - 150# ASME B16.5
- 8” (DN 200) - 300# ASME B16.5
- 8” (DN 200) - JIS 10K
- 8” (DN 200) - PN 10
- 8” (DN 200) - PN 16
- 8” (DN 200) - PN 25
- 8” (DN 200) - PN 40
Flange Size - 80” (DN 2000)
- 80” (DN 2000) - 150# (ASME B16.47, A)
- 80” (DN 2000) - PN 6
Flange Type
- Raised Face (RF)
- RTJ - Ring Typical Joint
Isolation
- All Inputs & Outputs are Galvanically Isolated
Load
- Current Output: ≤ 680
Materials of Construction
- Measuring Tube: AISI 316L Stainless Steel, 1.4401
- Measuring Tube: Carbon Steel
Measuring Error
- < ± 0.5 % of Measured Value
Measuring Range
- 0 to 66 feet/sec (0 to 20 metres/second)
Output
- 0 to 2,000 Hz - Frequency Output
- 4-20 mA
Output Format
- Current Output
- Pulse or Frequency Output
Power Supply
- 100-240 Vac, 48 to 63 Hz
- Low Voltage: 18-35 Vdc
- Low Voltage: 24 Vac
- Low Voltage: 24 Vdc
Process Temperature
- -170° to 500° C (-274° to 932° F)
Repeatability
- ± 0.2 % of Measured Value
Sensor, Probe Style
- Ultrasonic
Time Constant
- 0.025 to 99 seconds
Window Material