Accuracy
- ± 4 mm - 3010 C & 3020 C
- ± 6 mm - 3030 C
- Better than 0.2 %
Ambient Temperature Range
- -40° to 80° C (-40° to 176° F)
Applications
- Liquids & Solids in Virtually All Industries
- Water & Waste Water Management - 3010 C & 3020 C
Approvals & Certifications
- 3010 C & 3020 C: ATEX II 1 G, 1/2 G, 2 G EEx ia IIC T6
- 3010 C & 3020 C: EMC EN 61326: 1997 (Class A), EN 61326: 1997, A1: 1998
- 3010 C & 3020 C: LVD EN 61010-1: 2001
- CE
- NAMUR NE 53
BSP Connection
- G 1-1/2” Male - 3010 C
- G 2” Male - 3020 C
Consumption
- Power: 2.1 W, Max.
- Power: 4 VA, Max.
Deadband
- 0.8 Foot (0.25 Meter) - 3010 C
- 1.3 feet (0.4 Meter) - 3020 C
- 2 feet (0.6 Meter) - 3030 C
Diameter
- Outer Cable: 0.19” to 0.35” (5 to 9 mm)
Diaphragm Material
- Transducer: 316Ti Stainless Steel, 1.4542
Electrical Connectors
- Plug Connection
- Wire Cross Sections up to 2.5 mm²
Electrical Contacts
- Gold-Plated Sliding Contacts (I²C Bus)
Enclosure, Body Material
- 316L Stainless Steel, 1.4435
- ABS
- Plastic PBT (Polyester)
Environmental Protection
- IP20 (For Unassembled)
- IP40 (For Mounted into the Sensor without Cover)
- IP66
- IP68
Flange Material
- Compression Flange: 316L Stainless Steel (1.4435) - 3030 C
- Compression Flange: Polypropylene Homopolymer (PPH) - 3030 C
Frequency
- Ultrasonic: 35 kHz - 3030 C
- Ultrasonic: 54 kHz - 3020 C
- Ultrasonic: 70 kHz - 3010 C
Humidity
- 45 to 75 % Relative Humidity
Materials of Construction
- Ground Terminal: Stainless Steel (1.4571 / 1.4435)
Output
- 4-20 mA, 2-Wire or 4-Wire
Process Temperature
- -40° to 80° C (-40° to 176° F)
Storage Temperature
- -40° to 80° C (-40° to 176° F)
Supply Voltage
- 14-30 Vdc (For 2-Wire, EEx ia Instrument)
- 14-36 Vdc (For 2-Wire, Non Ex Instrument)
- 20-253 Vac, 50/60 Hz (For 4-Wire Instrument)
- 20-72 Vdc, 50/60 Hz (For 4-Wire Instrument)
System Pressure
- psi: -2.9 to 14.5 (kPa: -20 to 100, bar: -0.2 to 1) - 3030 C
- psi: -2.9 to 29 (kPa: -20 to 200, bar: -0.2 to 2) - 3010 C & 3020 C
Temperature Coefficient
- 0.06 % / 10K - Average Temperature Coefficient of Zero Signal
Temperature Range
- 18° to 30° C (64° to 86° F)
Vibration
- Resistance: 4 G at 5 to 100 Hz
Wetted Materials
- EPDM - Seal Transducer / Process Fitting
- Mounting Strap: 304 Stainless Steel, 1.4301 - 3030 C
- Process Fitting & Transducer: PVDF - 3010 C & 3020 C
- Process Fitting: Unsaturated Polyester (UP) - 3030 C
Window Material
- Polycarbonate - Inspection Window in Housing Cover
- Polyester Foil - Inspection Window