Specifications
- Developed for use in general industry and OEM applications, where versatility and economy are requirements
- Compact stainless steel construction with ceramic sensor
- Available ranges include Inches Hg: -30 up to psi: 0 to 5,000 (kPa: 0 to 34,474, bar: 344.7)
- Wide range of mechanical and electrical connections
- ±0.5% accuracy
- NEMA 4X / IP65 and IP67
- CE, CSA and RoHS compliant
- Approved for outdoor use
- Customizable
Displaying prices & availability for Ohio, United States in CAD. Change location.
Models matching criteria: 14
100+ In Stock
$1,925.00
CAD
$10.00 Shipping
50+ In Stock
$1,983.00
CAD
$10.00 Shipping
50+ In Stock
$1,505.00
CAD
$10.00 Shipping
50+ In Stock
$928.00
CAD
$10.00 Shipping
50+ In Stock
$240.00
CAD
$10.00 Shipping
50+ In Stock
$443.00
CAD
$10.00 Shipping
50+ In Stock
$481.00
CAD
$10.00 Shipping
50+ In Stock
$2,320.00
CAD
$10.00 Shipping
25+ In Stock
$1,634.00
CAD
$10.00 Shipping
25+ In Stock
$1,207.00
CAD
$10.00 Shipping
25+ In Stock
$2,038.00
CAD
$10.00 Shipping
21 In Stock
$1,808.00
CAD
$10.00 Shipping
14 In Stock
$140.00
CAD
$10.00 Shipping
3 In Stock
$1,481.00
CAD
$10.00 Shipping
Specifications
Brand
Accuracy
- ± 0.5 % of Full Scale Output
Approvals & Certifications
- CE
- CSA
- EMC Directive: 2004/108/EC
- PED: 97/23/EC (Module A), Valid for Devices With, Max.
- RoHS
BSP Connection
- G 1/4” Male (DIN 3852)
Burst Pressure
- psi: 44 to 6,527 (kPa: 303.4 to 45,000, bar: 3.034 to 450)
Cable Material
- Cable Outlet: PVC
Circuit Protection
- EMI/RFI Protected: Emission & Immunity According to EN 61326
- Reverse Polarity Protection
- Short Circuit Protected
Consumption
- Current Consumption 2-Wire: 25 mA - Max.
- Current Consumption 3-Wire Ratiometric: 1.5 mA
- Current Consumption 3-Wire Voltage: 5 mA (Short-Circuit Current 20 mA)
Diaphragm Material
- Ceramic AI₂O₃ 96 %
Electrical Connectors
- 1/2” NPT Female Conduit Fitting
- DIN 43650-A (ISO 4400)
- M12 x 1, 4-Pin
- Micro Connector (Contact Distance 9.4 mm)
Enclosure, Body Material
- 304 Stainless Steel
Environmental Protection
- IP65
- IP66
- IP67
- NEMA 4X
Frequency
- Measuring Rate: 1 kHz
Load
- 3-Wire: 10 kiloohms Min.
Load Effect
- 0.05 % of Full Scale Output / kiloohms
Materials of Construction
- Pressure Port: 304 Stainless Steel
NPT Connection
- 1/4” NPT Male
Output
- 2-Wire: 4-20 mA/Vs = 8-32 Vdc
- 3-Wire Ratiometric: 0.5-4.5 Vs / Vs = 5 ± 0.5 Vdc
- 3-Wire: 0-10 V/Vs = 14-30 Vdc
Overpressure & Static Pressure Limits
- Overpressure psi: 15 to 5,802 (kPa: 103.4 to 40,000, bar: 1.034 to 400)
Power Supply Effect
- 0.05 % of Full Scale Output / 10 V
Pressure Range
- bar: -1 to 344.7
- Inches Hg: -30 to 0
- kPa: -101.4 to 34,474
- psi: -14.7 to 5,000
Process Temperature
- -25° to 125° C (-13° to 257° F)
Response Time
- 2-Wire: < 10 milliseconds
- 3-Wire: < 3 milliseconds
Seat / Seal Material
- Seal: FKM
- Seal: Viton
Sensor, Probe Material
- Sensor: Ceramic
Shock
- 500 G, 1 millisecond According to DIN EN 60068-2-27
Stability
- Long-term Stability: < ± 0.3 % of Full Scale Output/Year at Reference Conditions
Storage Temperature
- -40° to 85° C (-40° to 185° F)
Temperature Effect
- < ± 0.5 % of Full Scale Output/10 K
Temperature Range
- Electronics Environment: -25° to 85° C (-13° to 185° F)
Vibration
- 10 G at 25 Hz to 2 kHz According to DIN EN 60068-2-6
- HVAC Systems
- Hydraulics & Pneumatics Sensing
- OEM Applications
- Pump & Compressor Monitoring
- Refrigeration Systems
- Suitable for All Process & Automation Control
- Use in General Industries