The G448 is a DIN rail mount, bridge or strain gauge input signal conditioner with 1,800 Vdc isolation between input, output and power.
The field configurable input and output offer flexible, wide ranging capability for bridge or strain gauge input applications from 0.5 mV/V to over 50 mV/V.
Wide ranging, precision zero and span pots allow 50% adjustability of offset and gain within each of the 11 switch selectable input ranges.
The output can be set for either 0 to 5 V, 0 to 10 V, 0 to 1 mA, 0 to 20 mA or 4-20 mA.
Features
Adjustable excitation 1 to 10 V with up to 120 mA drive
Field configurable inputs from 10 mV to ±200 mV (0.5 mV/V to >50 mV/V)
Field configurable outputs: 0 to 5 V, 0 to 10 V, 0 to 1 mA, 0 to 20 mA and 4-20 mA