UFM 600 T Ultrasonic Flowmeter - Wall Mounted System

Brand: Krohne

Clamp-on ultrasonic flowmeters for liquids. Efficient flowmetering and volume counting of clean, homogeneous liquids with low gas and solids contents.

Advantages of measuring from the outside
  • Non-contact measurement
  • No construction of the pipe cross-section
  • No additional pressure drop
  • No interruption of the process
  • Electrical conductivity, pressure, density, etc. have no effect on measurements
  • Easy to install
  • No maintenance requirement
  • Low power consumption
  • Low operating costs
Features
  • Wall mounted system
  • With CE approval to EN 50081-1 and EN 50082-1
  • Local display 
  • Current and pulse outputs 
  • RS 232 interface 
  • Status output

Specifications

Brand

Ambient Temperature Range

  • -25° to 60° C (-13° to 140° F)

Applications

  • Acids
  • Alkaline Solutions
  • Boiler Feedwater in Power Stations
  • Checking Other Flowmeters
  • Demineralized Water for Cooling Purposes
  • Oil
  • Pretreated Wastewater in Sewage Plants

Approvals & Certifications

  • CE to EN 50081-1, EN 50082-1
  • TÜV

Cable Length

  • Sensor Cable: 15 feet (5 metres)
  • Sensor Cable: 15 to 900 feet (5 to 300 metres) Optional

Current

  • Load: ≤ 150 mA - for Active Output
  • Load: ≤ 25 mA - for Active Output
  • Load: 100 mA - Max.

Diameter

  • 2” to 120” (50 to 3,000 mm)

Display

  • 3-Line LCD Display
  • Backlit

Electrical Connectors

  • BNC Connector
  • Coaxial Cable

Enclosure, Body Material

  • Nickel-Plated Brass

Environmental Protection

  • IP65
  • IP66
  • IP67
  • NEMA 4
  • NEMA 4X
  • NEMA 6

Frequency

  • 0.0028 to 10,000 Hz at Q=100 % - for Pulse Output

Input

  • 5-30 Vdc - for Pulse Output

Interface Connection

  • RS-232

Load

  • ≥ 1,000 ohms - for Active Output
  • ≥ 180 ohms - for Active Output

Materials of Construction

  • ALTOCLAMP Mounting Device: Anodized Aluminum
  • Pipeline: Ceramic
  • Pipeline: Metal
  • Pipeline: Plastic

Measuring Error

  • ± 1 to 3 % of Measured Value

Mounting

  • Wall Mounted

Output

  • 0.0028 to 10,000 Pulses/second
  • 0-20 mA

Output Format

  • Current Output
  • Pulse Output

Power

  • ≤ 10 VA - for AC Version
  • ≤ 8 W - for DC Version

Power Supply

  • 18-32 Vdc - for DC Version
  • 50 V from Signal Converter - for RS 600
  • 85-264 Vac - for AC Version

Pulse Range

  • Pulse Width: 160 µs
  • Pulse Width: 50 MicroSeconds
  • Pulse Width: 500 milliseconds

Sensor, Probe Style

  • Ultrasonic

Temperature Range

  • -25° to 120° C (-13° to 248° F)

Time Constant

  • 0.04 second - for Pulse Output
  • 0.04 to 3,600 seconds - for Current Output

  • Demineralized water for cooling purposes
  • Boiler feedwater in power stations
  • Pretreated wastewater in sewage plants
  • Checking other flowmeters
  • Oil
  • Acids
  • Alkaline solutions

show more