OPTISONIC 6300 P Ultrasonic Flowmeter
Brand: KrohneThe new OPTISONIC 6300 P flowmeter combines mobile, straightforward and quick liquid measurement with the proven precision and reliability of KROHNE ultrasonic technology.
Simply attach the sensor unit to the tube and connect the compact evaluation unit - now just read the results.
It is just as easy to use the device for data logging. Data is saved to a USB stick and transferred to external evaluation systems.
Its ease of use and flexibility make the OPTISONIC 6300 P the ideal solution for flow measurement in a variety of applications in virtually any sector of industry.
Specifications
Brand
Ambient Temperature Range
- Sensor: -40° to 70° C (-40° to 158° F)
- Signal Converter: -20° to 55° C (-4° to 131° F)
Applications
- Checking of Inline Flowmeters
- Checking of Pump Performance
- Commissioning of HVac Systems
- General Flow Related Problem Solving
- Temporary Replacement of Defective Flowmeters
Approvals & Certifications
- CE
- EMC Directive: 2004/108/EC, Harmonized Standard: EN 61326-1: 2006
- LVD Directive: 2006/95/EC, Harmonized Standard: EN 61010: 2001
Approvals & Certifications
- IEC 60068-2-27 (Shock Test Sensor), IEC 60068-2-64 (Vibration Test Sensor)
Battery Life
- Measuring Operation (Display at 50 % Brightness): 14 Hours
Communication
- USB
Consumption
- Maximum
Diagnostics
- Self Diagnostics: Bargraph
- Self Diagnostics: Empty Pipe Detection
- Self Diagnostics: Flowmeter
- Self Diagnostics: Measured Value
- Self Diagnostics: Process
Display
- 4.3” TFT with LED Backlight, Daylight Readable (272 x 480 Dots Resolution)
Environmental Protection
- IP10
- IP40
- IP65
- IP67
- NEMA 1
- NEMA 4
- NEMA 6
Humidity
- 5 to 80 %, Non-Condensing
Input
- 0(4)-20 mA (2x) with Optional I/O Box
Materials of Construction
- Converter: Polyamide PA12, Covered with TPE Soft Touch Layer on the Sides
- Pipe: Asbestos Cement
- Pipe: Ceramic
- Pipe: Metal
- Pipe: Plastic
- Trunk on Wheels: Polypropylene
Measuring Error
- Maximum
Media
- Liquids
Output
- 0-20 mA, Pulse, Frequency and/or Status Output
- 10-21.5 mA
- 4-20 mA
- Error Identification: 0-22 mA
Pipe Size
- 1/2 to 60”
Power Supply
- Adapter: 100-240 Vac (-10 % / 10 %) at 47 to 63 Hz
Principle of Operation
- Measuring Principle: Ultrasonic Transit Time
Process Temperature
- -40° to 120° C (-40° to 248° F)
Repeatability
- < ± 0.2 %
Sensor, Probe Material
- Sensor: Anodized Aluminum (Rail)
Storage Temperature
- -30° to 80° C (-22° to 176° F)
Viscosity
- < 100 cSt
Voltage
- Adapter: 13.2 V