FAIRCHILD Model T6000 Electro-Pneumatic I/P, E/P Transducer, Terminal Block, CSA, Intrinsically Safe, 4-20 mA Input, 0-120 psig Output

Price
$482.00 CAD
Stock
13 In Stock

  • Extended Output Range: 0-120 psig, 0-8 bar, 0-800 kPa
  • Extended Supply Pressure: 125-150 psig, 8.8-10 bar, 880-1000 kPa
  • Electrical Connections: Terminal Block
  • Underwriting Group: Canadian Standards
  • Approval Class: Intrinsically Safe
  • Temperature Range: -20°F to +150°F (-30°C to +65°C)
  • Input: 4-20mA
  • Materials of Construction:
    • Body & Housing: Aluminium
    • Trim: Zinc Plated Steel
    • Orifice: Nickel Plated Brass
    • Diaphragm: Nitrile

Specifications

Accuracy

  • 0.5 % to 1.0 % (Independent Linearity)

Air Consumption

  • Maximum

Approvals & Certifications

  • ATEX
  • CE
  • CSA
  • FM

BSP Connection

  • 1/4” BSPT Female

Elastomers

  • Nitrile

Electrical Connectors

  • 1/2” NPT Conduit Fitting with Pigtail
  • DIN 43650
  • Junction Box
  • Rack Mount
  • Terminal Block

Enclosure, Body Material

  • Aluminum

Environmental Protection

  • Dust Ignition-Proof
  • Explosion-proof
  • Intrinsically Safe
  • IP65
  • IP66
  • NEMA 4X / IP65, 66

Exhaust Capacity - Relieving Units Only

  • 2 scfm (3.4 m³/hour)

Flow Rate

  • 11 scfm (18.7 m³/hour) at psig: 150 (bar: 10, kPa: 1,000) Supply & Midscale Output - Extended Range
  • 2.5 scfm (4.25 m³/hour) at psig: 25 (bar: 1.7, kPa: 170) Supply & psig: 9 (bar: 0.6, kPa: 60) Output
  • 9 scfm (15.3 m³/hour) at psig: 120 (bar: 8, kPa: 800) Supply & psig: 9 (bar: 0.6, kPa: 60) Output

Hysteresis

  • 0.25 % of Full Scale
  • Less than 1.0 % of Full Scale at psig: 125 (bar: 8.8, kPa: 880)
  • Less than 1.0 % of Full Scale at psig: 35 (bar: 2.5, kPa: 250)
  • Less than 1.0 % of Full Scale at psig: 65 (bar: 4.6, kPa: 460)

Input

  • 4-20 mA
  • mA: 10-50
  • Vdc: 0-10
  • Vdc: 0-5
  • Vdc: 1-5
  • Vdc: 1-9

NPT Connection

  • 1/4” NPT Female

Orifice Material

  • Nickel-Plated Brass

Output Pressure

  • bar: 0 to 8
  • kPa: 0 to 800
  • psig: 0 to 120

Process Temperature

  • -30° to 65° C (-20° to 150° F)

Relief

  • Relieving

Repeatability

  • ≤ 0.1 % of Full Scale

RFI/EMI Effect

  • < 0.5 % of Span at 30 V/m Class 3 Band ABC (20-1,000 MHz) Per SAMA PMC 33.1 1978 & < 0.5 % of Span at 10 V/m Level, to 2 GHz Band Per EN 61,000-4-3: 1998 +A1 EMC Directive 89/336/EEC European Norms EN 61326

Signal Impedance

  • 3-Wire Voltage Input: 10 Kilohms

Span - Minimum

  • For Output Range psig: 0 to 120 - psig: 50 (bar: 3.5, kPa: 350)
  • For Output Range psig: 0 to 30 - psig: 12 (bar: 0.8, kPa: 80)
  • For Output Range psig: 0 to 60 - psig: 25 (bar: 1.5, kPa: 150)
  • For Output Range psig: 3 to 15 - psig: 5 (bar: 0.35, kPa: 35)
  • For Output Range psig: 3 to 27 - psig: 10 (bar: 0.7, kPa: 70)
  • For Output Range psig: 6 to 30 - psig: 10 (bar: 0.7, kPa: 70)

Span & Zero Adjustments

  • Screwdriver Adjustments Located on Front of Unit

Supply Pressure

  • For Output Range psig: 0 to 120: psig: 125 to 150 (bar: 8.8 to 10, kPa: 880 to 1,000)
  • For Output Range psig: 0 to 30: psig: 35 to 150 (bar: 2.5 to 10, kPa: 250 to 1,000)
  • For Output Range psig: 0 to 60: psig: 65 to 150 (bar: 4.6 to 10, kPa: 460 to 1,000)
  • For Output Range psig: 3 to 15: psig: 20 to 120 (bar: 1.5 to 8, kPa: 150 to 800)
  • For Output Range psig: 3 to 27: psig: 32 to 120 (bar: 2.2 to 8, kPa: 220 to 800)
  • For Output Range psig: 6 to 30: psig: 35 to 120 (bar: 2.4 to 8, kPa: 240 to 800)

Supply Pressure Effect

  • psig: 0.25 (bar: 0.17, kPa: 1.7) for a psig: 25 (bar: 1.7, kPa: 170) Change in Supply Pressure

Supply Voltage

  • 3-Wire Voltage Input: 7.2-30 Vdc, less than 3 mA

Trim Material

  • Brass
  • Zinc-Plated Steel

Vent

  • Straight

Similar SKUs

TTCI6000-405
TTCI6000-405
Model T6000 Electro-Pneumatic Pressure Transducer
Fairchild
$555.00 CAD
50+ In Stock
FAIRCHILD Model T6000 Electro-Pneumatic I/P, E/P Transducer, Terminal Block, CSA, Intrinsically Safe, 4-20 mA Input, 0-60 psig Output
TACI6000-406
TACI6000-406
Model T6000 Electro-Pneumatic Pressure Transducer
Fairchild
$540.00 CAD
50+ In Stock
FAIRCHILD Model T6000 Electro-Pneumatic I/P, E/P Transducer, 1/2" NPT Conduit Fitting with Pigtail, CSA, Intrinsically Safe, 4-20 mA Input, 0-120 psig Output
TTCI6000-404
TTCI6000-404
Model T6000 Electro-Pneumatic Pressure Transducer
Fairchild
$348.00 CAD
100+ In Stock
FAIRCHILD Model T6000 Electro-Pneumatic I/P, E/P Transducer, Terminal Block, CSA, Intrinsically Safe, 4-20 mA Input, 0-30 psig Output
TTCI6000-401
TTCI6000-401
Model T6000 Electro-Pneumatic Pressure Transducer
Fairchild
$464.00 CAD
100+ In Stock
FAIRCHILD Model T6000 Electro-Pneumatic I/P, E/P Transducer, Terminal Block, CSA, Intrinsically Safe, 4-20 mA Input, 3-15 psig Output
TA6000-406
TA6000-406
Model T6000 Electro-Pneumatic Pressure Transducer
Fairchild
$996.00 CAD
25+ In Stock
FAIRCHILD Model T6000 Electro-Pneumatic I/P, E/P Transducer, 1/2" NPT Conduit Fitting with Pigtail, 4-20 mA Input, 0-120 psig Output
TT6000-406
TT6000-406
Model T6000 Electro-Pneumatic Pressure Transducer
Fairchild
$147.00 CAD
18 In Stock
FAIRCHILD Model T6000 Electro-Pneumatic I/P, E/P Transducer, Terminal Block, 4-20 mA Input, 0-120 psig Output
TTCI6000-402
TTCI6000-402
Model T6000 Electro-Pneumatic Pressure Transducer
Fairchild
$1,395.00 CAD
17 In Stock
FAIRCHILD Model T6000 Electro-Pneumatic I/P, E/P Transducer, Terminal Block, CSA, Intrinsically Safe, 4-20 mA Input, 3-27 psig Output
TT7800-406
TT7800-406
Model T7800 Electro-Pneumatic I/P, E/P Transducer
Fairchild
$1,323.00 CAD
25+ In Stock
FAIRCHILD Model T7800 Electro-Pneumatic I/P, E/P Transducer, Terminal Block, 4-20 mA Input, 0-120 psig Output