PD6830-AXA-I-2

Price
$301.00 CAD
Stock
50+ In Stock

  • Product Type: Decimal Modbus Scanner
  • Inputs: (16 Total): Modbus RTU; (One) Pulse
  • Outputs: (2) Open Collectors, (1) 4-20 mA Output
  • Power: 9-30 VDC
  • Display: Dual Line, 0.7" & 0.4" High, 5 & 7 Digits, Decimal, LCD
  • Serial Communications: RS-485 Modbus
  • Backlight: Standard
  • Approvals: ATEX (FP), CE, CSA (XP), FM (XP), IEC (FP)
  • Warranty: 3 Years

Specifications

Approvals & Certifications

  • ATEX II 2 GD Ex d IIC T6 Gb Ex Tb IIIC T85° C Db IP68 Tamb -40° to 75° C ATEX Certificate: Sira 10-ATEX-1116X
  • CSA Class I, Div. 1, Groups B, C, D, Class II, Div. 1, Groups E, F, G Class III, Div. 1, Ex d IIC T6 Enclosure Typical 4X, IP66/68: Ta = -40° to 75° C, Certificate Number: 2325749
  • FM Class I, Div. 1, Groups B, C, D Class II, Div. 1, Groups E, F, G Class III, Div. 1, T6 Class I, Zone 1, AEx d IIC T6 Gb Zone 21, AEx Tb IIIC T85° C Ta = -40° to 75° C Enclosure: Typical 4X & IP66 Certificate Number: 3040391
  • IEC Ex d IIC T6 Gb Ex Tb IIIC T85° C Db IP68 Ta = -40° to 85° C IECEx Certificate: IECEx SIR 10.0056X

Environmental Protection

  • IP66
  • IP68
  • NEMA 4X
  • NEMA 7
  • NEMA 9

Decimal Display

  • Top Display: Five Digits (0 to 99999), 0.7” (17.8 mm) high, 7-segment, automatic Lead Zero Blanking.
  • Bottom Display: Seven Characters, 0.4” (10.2 mm) High, 14-segment, automatic Lead Zero Blanking.
  • Symbols: Total, grand total, high Alarm, Low Alarm, SafeTouch Button Sleep mode/disable, password lock.

Feet & Inches Display

  • Top Display: 0.60” (15.2 mm) high, 0 to 399FT, 1115/16 IN, 7-segment, Programmable 1/16 or 1/8 fraction display.
  • Bottom Display: Seven Characters, 0.4” (10.2 mm) High, 14-segment, 7-digits.
  • Tank Level Indicator: 20-segments, F (Full) and E (Empty).
  • Alarm Indication: High and Low Alarm
  • Backlight: White

Display Assignment

  • Top and Bottom Display*: Process Variables (PV), Alternating PV and Units, Tag and PV, or Tag, PV, and Units, Pulse Input Rate, Total, or Grand Total with Alternating Tag.
  • Bottom Display: All Top Display Options or Off
  • Units and tag independent for each PV, pulse Input rate, total, and grand total.
  • *Note: on feet and inches display models, top display used only for level Modbus process variables or math channels.

Backlight

  • White LED, 10 sec auto-off when battery Powered. Backlight deactivated below Temperature ≈ -20° C

Alarm Indication

  • Flashing display plus HI/LO (Alarm) or SET indicators.

Scan & Update Rate

  • Ambient > -20° C: Modbus PV scan rate Programmable from 2 to 99 seconds per PV. Tag and units Programmable for 1 to 5 second alternation. Pulse Input variables update 1/second. Rate update is dependent on gate settings.
  • Ambient < -20° C: All Modbus scan, alternating units and tags, and pulse Input variables update/10 seconds minimum.

Underrange

  • Lower Display: Flashes -999999
  • Upper Display: Decimal display flashes -9999
  • Level display flashes to 399FT 1115/16 IN

Overrange

  • Lower Display: Flashes 9999999
  • Level display flashes to 399FT 1115/16 IN
  • Upper Display: Decimal display flashes 99999

Programming Method

  • Four SafeTouch through-glass buttons when cover is installed. Four internal push buttons when cover is removed

Recalibration

  • Calibrated at the factory to Read frequency in Hz. No recalibration Required

Password Menu Options

  • Three Programmable password selections can be used for the following: Restrict modification of settings, prevent resetting the total or grand total without the password, or permanently lock out the ability to change or reset the grand total or any grand total Related settings (making a Non-Resettable grand total).
  • Pass: Restricts modifications of programmed settings to Require re-entering the password to make changes.
  • Pass T: Restricts the reset of total to Require re-entering the password. Disables the manual mode reset Contact.
  • Pass GT: Restricts the reset of grand total to Require re-entering the password. May enable a Non-Resettable grand total and permanent lockout of grand total-Related settings with a Specific password.

Input Power

  • 9-30 Vdc, 38 mA Max. 2.2 W

Data Logging

  • Up to 512 records, recorded 4/day at Specific times or at defined time intervals. Record Contains first eight enabled Modbus PVs, C1-4 if enabled, date, time, pulse rate, total, and grand total with units, and log number.

Isolation: All Models

  • 500 V opto-Isolated pulse Input-to-Power/OC output with isolated Input enabled, 500 V Input/power-to-RS-485 Serial communications. AXA Models: 500 V Input/power-to-analog output.

Environmental

  • Operating Temperature Range: -40 to 75° C, Storage Temperature Range: -40 to 75° C, Backlight deactivated below Temperatures ≈ -20° C, Relative Humidity: 0 to 90 % Non-Condensing

Non-Volatile Memory

  • All programmed settings and total Reading are stored in non-volatile memory for a minimum of ten years if power is lost.

Connections

  • Screw terminals accept 12 to 22 AWG wire

Enclosure

  • Explosion-proof die-Cast aluminum with glass window, corrosion-resistant epoxy coating, color: Blue. NEMA 4X, 7, & 9, IP68. Copper-Free (0.3 %). Default conduit connections: Three 3/4” NPT threaded conduit openings. One 3/4” NPT metal plug with 12 mm hex key fitting installed. Additional conduit opening configurations and plugs may be available; verify quantity and sizes on specific device labeling during installation

Mounting

  • May be mounted directly to conduit. Two slotted flanges for wall mounting or NPS 1-1/2” to 2-1/2” or DN 40 to 65 mm pipe mounting.

Display Orientation

  • Display may be Mounted at 90° increments up to 270° from default orientation

Overall Dimensions

  • 5.67” x 5.24” x 4.88” (144 mm x 133 mm x 124 mm) (W x H x D)

Weight

  • 5.00 lbs (80 oz., 2.27 kg)

Warranty

  • 3 Years Parts and Labor
show more