The field configurable AP4380 isolator offers wide ranging input and output capability for scaling and transmitting analog DC signals. 

The AP4380-2000 will accept input voltage spans from 10mV up to 100 volts, as well as input current spans from 1mA to 100mA. 

The AP4380-2001 will accept input voltages up to 200V, as well as the same input current ranges.The input zero and span potentiometers enable 50% input zero and span adjustability. For example, the 0-10V input range can be elevated to 5-10V, compressed to 0-5V or set to 2.5 - 7.5V. 

The AP4380 offers four (4) popular output ranges: 0-5V, 0-10V, 0-1mA and 4-20mA. The 4-20mA compliance is a powerful 20VDC. 

Model AP4380 can be configured to accept bipolar input ranges and offers selectable normal or reverse acting operation.

The AP4380 is a 3-port industrial isolator -- the output is optically isolated from its input up to 1500 VDC. The ASIC*-based I/O channel is independently transformer isolated from the selectable 120/240VAC power supply
Features
  • Eliminates ground loops
  • 50% Adjustable field configurable input ranges: 10 mV to 100 V (200 V on -2001), 1 to 100 mA
  • Four field configurable output ranges: 0 to 5 V, 0 to 10 V, 0 to 1 mA, 4 to 20 mA
  • Plug-in Installation
  • Selectable 120/240 Vac power (9 to 30 Vdc available)
  • ASIC Technology for enhanced reliability

Models matching criteria: 18
  • Input Voltages - Up to 200 Volts
  • Coating - Without
  • Line Power - 9 to 30 VDC, Inverter Isolated
  • Factory Calibration - Without
100+ In Stock
$1,816.00 CAD
$10.00 Shipping
  • Input Voltages - Up to 100 Volts
  • Coating - Urethane Coating of Internal Circuitry for Protection From Corrosive Atmospheres
  • Line Power - Standard
  • Factory Calibration - With
100+ In Stock
$678.00 CAD
$10.00 Shipping
  • Input Voltages - Up to 200 Volts
  • Coating - Urethane Coating of Internal Circuitry for Protection From Corrosive Atmospheres
  • Line Power - Standard
  • Factory Calibration - With
100+ In Stock
$2,051.00 CAD
$10.00 Shipping
  • Input Voltages - Up to 200 Volts
  • Coating - Urethane Coating of Internal Circuitry for Protection From Corrosive Atmospheres
  • Line Power - 9 to 30 VDC, Inverter Isolated
  • Factory Calibration - With
100+ In Stock
$2,445.00 CAD
$10.00 Shipping
  • Input Voltages - Up to 200 Volts
  • Coating - Without
  • Line Power - Standard
  • Factory Calibration - With
100+ In Stock
$1,972.00 CAD
$10.00 Shipping
100+ In Stock
$71.00 CAD
$10.00 Shipping
  • Input Voltages - Up to 200 Volts
  • Coating - Urethane Coating of Internal Circuitry for Protection From Corrosive Atmospheres
  • Line Power - Standard
  • Factory Calibration - Without
50+ In Stock
$1,919.00 CAD
$10.00 Shipping
Eurotherm Field Configurable Isolator - 100Vdc Maximum view more
  • Input Voltages - Up to 100 Volts
  • Coating - Without
  • Line Power - Standard
  • Factory Calibration - Without
50+ In Stock
$2,195.00 CAD
$10.00 Shipping
  • Input Voltages - Up to 100 Volts
  • Coating - Without
  • Line Power - Standard
  • Factory Calibration - With
25+ In Stock
$2,034.00 CAD
$10.00 Shipping
  • Input Voltages - Up to 100 Volts
  • Coating - Urethane Coating of Internal Circuitry for Protection From Corrosive Atmospheres
  • Line Power - 9 to 30 VDC, Inverter Isolated
  • Factory Calibration - With
25+ In Stock
$294.00 CAD
$10.00 Shipping
25+ In Stock
$635.00 CAD
$10.00 Shipping
  • Input Voltages - Up to 100 Volts
  • Coating - Without
  • Line Power - 9 to 30 VDC, Inverter Isolated
  • Factory Calibration - With
25+ In Stock
$731.00 CAD
$10.00 Shipping
  • Input Voltages - Up to 100 Volts
  • Coating - Without
  • Line Power - 9 to 30 VDC, Inverter Isolated
  • Factory Calibration - Without
13 In Stock
$424.00 CAD
$10.00 Shipping
  • Input Voltages - Up to 100 Volts
  • Coating - Urethane Coating of Internal Circuitry for Protection From Corrosive Atmospheres
  • Line Power - Standard
  • Factory Calibration - Without
11 In Stock
$1,322.00 CAD
$10.00 Shipping
  • Input Voltages - Up to 200 Volts
  • Coating - Urethane Coating of Internal Circuitry for Protection From Corrosive Atmospheres
  • Line Power - 9 to 30 VDC, Inverter Isolated
  • Factory Calibration - Without
9 In Stock
$1,341.00 CAD
$10.00 Shipping
Eurotherm Field Configurable Isolator - 200vcd Maximum view more
  • Input Voltages - Up to 200 Volts
  • Coating - Without
  • Line Power - Standard
  • Factory Calibration - Without
8 In Stock
$2,200.00 CAD
$10.00 Shipping
  • Input Voltages - Up to 100 Volts
  • Coating - Urethane Coating of Internal Circuitry for Protection From Corrosive Atmospheres
  • Line Power - 9 to 30 VDC, Inverter Isolated
  • Factory Calibration - Without
6 In Stock
$2,434.00 CAD
$10.00 Shipping
  • Input Voltages - Up to 200 Volts
  • Coating - Without
  • Line Power - 9 to 30 VDC, Inverter Isolated
  • Factory Calibration - With
5 In Stock
$2,009.00 CAD
$10.00 Shipping

Specifications

Approvals & Certifications

  • CSA C22.2 No. M1982
  • IEC 801-2
  • UL (C,US), 508

Full Scale Range

  • 2000 Series: 10 mV to 100 V
  • 2001 Series: 10 mV to 200 V

Impedance

  • > 100K ohms

Output

  • Voltage Output: 0-5 V or 0-10 V
  • Current Output: 0-1 mA or 4-20 mA

Compliance

  • 0-1 mA: 10 V Max.
  • 4-20 mA: 20 V Max.

Response Time

  • 200 Miliseconds

Temperature Range

  • -15° C to 60° C
  • 5° F to 140° F

Power Consumption

  • 3 W Typical, 5 W max