LM3 Slim Line All-Purpose Submersible Transmitter
Brand: Winters Instruments
Specifications
- Slimline probe is especially suited for applications with restricted space
- Designed for continuous level measurement in water or other liquids with low viscosity
- 316L Stainless Steel probe with stainless steel sensor for ease in cleaning
- Available ranges from Inches WC: 0 to 400 up to psi: 0 to 300 (kPa: 0 to 2,068, bar: 0 to 20.68)
- ±0.35% accuracy rating
- NEMA 6P / IP68
- Approved for outdoor use
- Customizable
Displaying prices & availability for Ohio, United States in CAD. Change location.
Models matching criteria: 14
100+ In Stock
$774.00
CAD
$10.00 Shipping
50+ In Stock
$2,190.00
CAD
$10.00 Shipping
50+ In Stock
$1,913.00
CAD
$10.00 Shipping
50+ In Stock
$1,260.00
CAD
$10.00 Shipping
50+ In Stock
$1,583.00
CAD
$10.00 Shipping
50+ In Stock
$1,756.00
CAD
$10.00 Shipping
50+ In Stock
$167.00
CAD
$10.00 Shipping
25+ In Stock
$2,236.00
CAD
$10.00 Shipping
25+ In Stock
$945.00
CAD
$10.00 Shipping
25+ In Stock
$2,384.00
CAD
$10.00 Shipping
25+ In Stock
$2,250.00
CAD
$10.00 Shipping
21 In Stock
$1,704.00
CAD
$10.00 Shipping
16 In Stock
$563.00
CAD
$10.00 Shipping
15 In Stock
$849.00
CAD
$10.00 Shipping
Specifications
Brand
Accuracy
- 5 (kPa: 34.47, bar: 0.3447): 5 (kPa: 34.47, bar: 0.3447): < ± 0.25 % of Full Scale Output BFSL
Approvals & Certifications
- CE
- CSA
- EMC (Electromagnetic Compatibility): Emission & Immunity According to EN 61326
- RoHS
Burst Pressure
- psi: 22 to 1,740 (kPa: 151.7 to 12,000, bar: 1.517 to 120)
Cable Material
- Cable with Sheath: FEP (Black)
- Cable with Sheath: PUR (Black)
- Cable with Sheath: PVC - Grey
Capacitance
- Cable Capacitance (Signal Line / Shield & Signal Line / Signal Line): 160 PF/m
Circuit Protection
- Reverse Polarity Protection
Compensated Temperature
- 0° to 70° C (32° to 158° F)
Consumption
- Current: 25 mA - Max.
Diaphragm Material
- 316L Stainless Steel
Enclosure, Body Material
- 316Ti Stainless Steel
Environmental Protection
- IP67
- IP68
- NEMA 6P
Inductance
- Cable Inductance (Signal Line/Shield & Signal Line/Signal Line): 1 µH/m
Load Effect
- 0.05 % of Full Scale Output / kiloohms
Nominal Pressure
- psi: 0 to 15 (kPa: 0 to 103.4, bar: 0 to 1.034)
Output
- 2-Wire: 4-20 mA/Vs = 12-36 Vdc
Overpressure & Static Pressure Limits
- Overpressure psi: 15 to 1,450 (kPa: 103.4 to 10,000, bar: 1.034 to 100)
Power Supply Effect
- 0.05 % of Full Scale Output / 10 V
Pressure Range
- bar: 0 to 20.7
- Inches WC: 0 to 400
- kPa: 0 to 2,068
- psi: 0 to 300
Process Temperature
- -10° to 70° C (14° to 158° F)
Response Time
- < 10 milliseconds
Seat / Seal Material
- Seal: EPDM (Nordel)
- Seal: FKM
- Seal: Kalrez
- Seal: Viton
Sensor, Probe Material
- Probe: 316L Stainless Steel
- Sensor: Stainless Steel for Ease in Cleaning
Stability
- Long Term Stability: < ± 0.1 % of Full Scale Output/Year
Storage Temperature
- -25° to 70° C (-13° to 158° F)
Temperature Effect
- TC, Average: ± 0.07 % to ± 0.3 % of Full Scale Output/10 K
- Tolerance Band: < ± 0.75 % to < ± 2 % of Full Scale Output
- Appropriate for All Hazardous Areas Where An Intrinsically Safe Rating is Required
- Chemical & Sewage Treatment Installations
- Designed for Continuous Level Measurement in Water or other Liquids with Low Viscosity
- Oil & Gas Applications