Pressure control in systems with low flow requirements. Designed for cartridge fitment in manifold block or to relief to atmosphere in a tank or sump application.
Features
Set Point Repeatability ±2%
Set Point Range - user specified up to 800 bar
Sealing Re-Seat Pressure - Virtually zero leakage re-seat pressure ≥ 90% of cracking pressure
Orifice Size: Ø 4 mm
Back Pressure - set point is not affected by vent back pressure. Maximum permissible back pressure 100 bar
Operating Media - mineral oils, water glycol fluids and some chemicals