Accuracy
- When Distance 33 feet (10 metres): ± 0.03 % of Measured Distance
Alarm
- Error Signal of High: 22 mA
- Error Signal of Low: 3.6 mA
Ambient Temperature Range
- -40° to 80° C (-40° to 175° F)
Applications
- Level Measurement of Liquids, Pastes & Slurries
- Process Tanks
- Storage Tanks
- Tanks with Agitators
- Torpedo Ladles (Foundries)
- Wave Height
Approvals & Certifications
- ATEX: Ex ia IIC T3 to T6 + DIP, Ex d[ia] IIC T3 to T6 + DIP, Ex ia IIC T3 to T6 + DIP + WHG, Ex d[ia] IIC T3 to T6 + DIP + WHG, 3 G Ex NA II T3 to T6
- CE
- CRN
- CSA: IS Class I/II/III, Div. 1, Groups A, B, C, D, E, F, G, Class I, Zone 0, Ex ia IIC T3 to T6, XP-IS/DIP Class I/II/III, Div. 2, Groups A to D, F, G, Class I, Zone 0, Ex d IIC T3 to T6
- DNV: Ex ia IIC T6 to T3 Ga, Ex ia IIIC T70° to T95° C Da IP6X, Ex d [ia Ga] IIC T6 to T3 Ga/Gb, Ex Tb [ia Da] IIIC T70° to T95° C Db IP6X
- EAC
- EMC Directive 2004/108/EC in Conjunction with EN 61326-1 (2013)
- FCC
- FM: IS Class I/II/III, Div. 1, Groups A, B, C, D, E, F, G, Class I, Zone 0, AEx ia IIC T3 to T6, XP-IS/DIP Class I/II/III, Div. 1, Groups A, B, C, D, E, F, G, Class I, Zone 0, AEx d [ia] IIC T3 to T6
- IEC Ex: Ex ia IIC T2 to T6 + DIP, Ex d Ia IIC T2 to T6 + DIP
- INMETRO: Ex ia IIC T3 to T6 + DIP, Ex d Ia IIC T3 to T6 + DIP
- KGS: Ex ia IIC T3 to T6 + DIP, Ex d[ia] IIC T3 to T6 + DIP
- LVD 2006/95/EC in Conjunction with EN 61010-1 (2001)
- NAMUR NE 21, 43
- NEPSI Ex ia IIC T3 to T6 + DIP, Ex d Ia IIC T3 to T6 + DIP
- RSS-210
- WHG Z-65.16-425
Approvals & Certifications
- Calibration
- R & TTE Directive 1999/5/EC in Conjunction with ETSI EN 302 372-2, ETSI EN 302 729-2
Cable Material
- Cable Gland: Metal
- Cable Gland: Plastic
Diameter
- Diameter of the Outer Sheath of the Cable: 0.28” to 0.47” (7 to 12 mm)
Display
- 9 Lines, 160x160 Pixels in 8-Step Grayscale with 4-Button Keypad
- Integrated LCD Display with Sun Cover [-20° to 60° C (-4° to 140° F)]
Electrical Connectors
- Cable Entry Capacity (Terminal): 0.5 to 1.5 mm²
Enclosure, Body Material
- 316L Stainless Steel, 1.4401
- Polyester Coated Aluminum
Environmental Protection
- IP66
- IP67
- NEMA 4X
- NEMA 6P
- Weatherproof
Flange Size - 1-1/2” (DN 40)
- 1-1/2” (DN 40) - 150# (RF ASME B16.5)
- 1-1/2” (DN 40) - 1500# (RJ ASME B16.5)
- 1-1/2” (DN 40) - 300# (RF ASME B16.5)
- 1-1/2” (DN 40) - 600# (RF ASME B16.5)
- 1-1/2” (DN 40) - 900# (RJ ASME B16.5)
- 1-1/2” (DN 40) - JIS 10K
- 1-1/2” (DN 40) - PN 40
- 1-1/2” (DN 40) - PN 100
- 1-1/2” (DN 40) - PN 63
Flange Size - 2” (DN 50)
- 2” (DN 50) - 150# (RF ASME B16.5)
- 2” (DN 50) - 1500# (RF ASME B16.5)
- 2” (DN 50) - 300# (RF ASME B16.5)
- 2” (DN 50) - 600# (RF ASME B16.5)
- 2” (DN 50) - 900# (RJ ASME B16.5)
- 2” (DN 50) - JIS 10K
- 2” (DN 50) - PN 100
- 2” (DN 50) - PN 40
- 2” (DN 50) - PN 63
Flange Size - 3” (DN 80)
- 3” (DN 80) - 150# (RF ASME B16.5)
- 3” (DN 80) - 300# (RF ASME B16.5)
- 3” (DN 80) - 600# (RF ASME B16.5)
- 3” (DN 80) - 900# (RF ASME B16.5)
- 3” (DN 80) - JIS 10K
- 3” (DN 80) - PN 100
- 3” (DN 80) - PN 40
- 3” (DN 80) - PN 63
Flange Size - 4” (DN 100)
- 4” (DN 100) - 150# (RF ASME B16.5)
- 4” (DN 100) - 300# (RF ASME B16.5)
- 4” (DN 100) - 600# (RF ASME B16.5)
- 4” (DN 100) - 900# (RF ASME B16.5)
- 4” (DN 100) - JIS 10K
- 4” (DN 100) - PN 100
- 4” (DN 100) - PN 16
- 4” (DN 100) - PN 40
- 4” (DN 100) - PN 63
Flange Size - 6” (DN 150)
- 6” (DN 150) - 150# (RF ASME B16.5)
- 6” (DN 150) - 300# (RF ASME B16.5)
- 6” (DN 150) - PN 100
- 6” (DN 150) - PN 16
- 6” (DN 150) - PN 40
- 6” (DN 150) - PN 63
Flange Size - 8” (DN 200)
- 8” (DN 200) - 150# (RF ASME B16.5)
- 8” (DN 200) - PN 16
- 8” (DN 200) - PN 40
Flange Type
- Raised Face (RF)
- RTJ - Ring Typical Joint
Materials of Construction
- Weather Protection: 304 Stainless Steel, 1.4301
Measuring Range
- Up to 260 feet (80 metres)
NPT Connection
- 1-1/2” NPT (ASME B1.20.1)
Operating Pressure
- Drop Antenna (PP): psig: -14.5 to 232 (kPa: -100 to 1,600, bar: -1 to 16)
- Drop Antenna (PTFE) & Horn/Sheet Metal Horn Antenna: psig: -14.5 to 580 (kPa: -100 to 4,000, bar: -1 to 40)
- Horn/Sheet Metal Horn Antenna: psig: -14.5 to 1,450 (kPa: -100 to 10,000, bar: -1 to 100)
- Hygienic Antenna (PEEK): psig: -14.5 to 145 (kPa: -100 to 1,000, bar: -1 to 10)
Output
- 3.8-20.5 mA According to NAMUR NE 43
- 4-20 mA / HART
- Current Output: 16 mA HART
Power Supply
- Terminals Output 1 - Ex d: 20-36 Vdc for an Output of 22 mA at the Terminal
- Terminals Output 1 - Non-Ex / Ex I: 14-30 Vdc for an Output of 22 mA at the Terminal
- Terminals Output 2 - Non-Ex / Ex I / Ex d: 10-30 Vdc for an Output of 22 mA at the Terminal
Process Connection Material
- 316L Stainless Steel, 1.4401
- Hastelloy C-22 (2.4602)
Process Temperature
- Drop Antenna (PP): -40° to 100° C (-40° to 210° F)
- Horn/Sheet Metal Horn Antenna & Drop Antenna (PTFE): -50° to 150° C (-58° to 300° F)
- Horn/Sheet Metal Horn Antenna: -50° to 200° C (-58° to 390° F)
- Hygienic Antenna (PEEK): -20° to 150° C (-4° to 300° F)
Seat / Seal Material
- Seal: EPDM
- Seal: FKM
- Seal: FPM
- Seal: Kalrez 6375
Storage Temperature
- -40° to 85° C (-40° to 185° F)
Temperature Range
- PEI: -50° to 200° C (-58° to 390° F) - Max.
Vibration
- IEC 60068-2-6 & EN 50178: 1 G, 57 to 150 Hz - Vibration Resistance
- IEC 60068-2-6 & EN 50178: 10 to 57 Hz, 0.075 mm - Vibration Resistance
Wetted Materials
- 316L Stainless Steel, 1.4401
- Hastelloy C-22 (2.4602)
- PEEK
- Polypropylene (PP)
- PTFE